HC Series 19-inch rack-mount LiFePO4 battery, 5.12–16.08 kWh

The same 51.2 V platform in a 19-inch chassis — 440 mm wide, 2U to 5U depending on capacity, for cabinets, telecom racks and containerised systems.

HC Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
19-inch rack-mount LiFePO4 battery, 51.2 V
Typical applications
Telecom and data cabinets, rack ESS, containerised storage, UPS battery replacement
Models in range
HC 51.2V100Ah, HC 51.2V206Ah, HC 51.2V280Ah, HC 51.2V314Ah
Category
Storage Batteries

Why rack format

A rack chassis is a serviceability decision. In a telecom shelter or an IT room, the battery is one of several items in the cabinet, and the technician who replaces it is usually not a battery specialist. Slide-out rails, front terminals and a front-panel state-of-charge display reduce that job to unplugging two connectors.

The HC uses a 440 mm chassis — the 19-inch standard — with depth and height scaled by capacity. The 100 Ah module is 2U-class and 40 kg; the 314 Ah module is larger and 117 kg, which is a two-person lift onto the rails.

Parallel operation and addressing

Modules parallel on a common DC bus with a shared CAN bus for addressing. The master reports to the inverter as a single battery with the summed capacity; each module keeps its own protection, so a fault in one removes that module from the string rather than the whole bank.

For a 48 V rack, four 314 Ah modules give 64 kWh in a single cabinet — enough for a small commercial peak-shaving or backup duty, with the same inverter interface as a single module.

Charging in a rack environment

The common failure in rack installations is not the battery but the charger. Rectifiers built for lead-acid float at 54 V and will not fully charge a 51.2 V LiFePO4 module; they also lack the current limit the BMS expects at the top of the curve. Where a legacy rectifier cannot be reprogrammed, specify the module with a reduced charge current setting and accept a lower state of charge, or replace the rectifier.

Key Features

  • 19-inch chassis, 440 mm wide, 2U to 5U by capacity
  • 51.2 V, 100 / 206 / 280 / 314 Ah — 5.12 to 16.08 kWh
  • Smart BMS with 100–200 A continuous charge and discharge
  • Bluetooth and Wi-Fi standard; CAN and RS485 for hybrid inverters
  • Front-panel LCD and status LEDs
  • Rack ears and rail kit included
  • Parallel modules with automatic addressing
  • Optional BMS firmware for third-party hybrid inverter protocols

Applications

Telecom and IT cabinets

Fits a standard 19-inch rack beside rectifiers and switches, replacing a lead-acid string at a third of the weight.

Rack ESS for small commercial sites

Two to four modules per cabinet give 10–64 kWh in the footprint of a network rack.

Containerised and mobile storage

Rack mounting survives transport better than floor-standing cabinets and simplifies service access.

FAQ

What rack depth do I need?
600 mm for the 100 Ah module, 745 mm for the 280 and 314 Ah modules plus cable bend radius. A 800 mm cabinet covers every model with room for the breaker.
Is it a drop-in replacement for a lead-acid rack string?
Mechanically yes, electrically only if the charger has a LiFePO4 profile. Send the rectifier or UPS model and we will confirm the charge voltage and current limits.
Can modules be hot-swapped?
Not on the DC bus. Isolate the module string and the BMS before unplugging; the parallel architecture keeps the rest of the cabinet running.
How is heat handled?
Passive cooling through the front and rear vents, no fans. Keep 1U free above the top module in a closed cabinet.

Specification reference

Parameter HC 51.2V100AhHC 51.2V206AhHC 51.2V280AhHC 51.2V314Ah
General
Case design rack-mounted
Battery Type LiFePO4
Electrical
Normal Voltage(Vdc) 51.2V
Normal Capacity (25℃ 0.2C) (Ah) 100Ah206Ah280Ah314Ah
Normal Energy (25℃ 0.2C) (Wh) 5120Wh10547Wh14336Wh16076Wh
Float Charge Voltage(Vdc) 56.0V
Operating Voltage Range (Vdc) 40.0~58.4V
Max. Charge Current(A) 100A200A200A200A
Max. Discharge Current(A) 100A200A200A200A
Terminal M6M8M8M8
Environment
Storage temperature 0 °C~30 °C
BMS & protection
IP degree IP 20
Storage duration ≤6 25 °C 6 months at 25 °C
Safety standard UN38.3,MSDS
Display LCD
Communication CAN, RS485, Bluetooth, WIFI
Protection Overcharge protection, Overdischarge protection, Overcurrent protection, Shortcircuit protection, Overtemperature protection
Environment
Working Temperature Charge 0 °C~+50 °C;Discharge -20 °C~+50 °C
Humidity 0~95%(no condensation)
Sea Level(m) 4000m (Derating above 2000m)
Mechanical & packing
LxWxH (products size, mm) 440X440X133mm600*440*240 mm745*440*240 mm745*440*240 mm
LxWxH (package size, mm) 554X520X196mm700X540x405mm840*520*430 mm840*520*430 mm
NW (Kg) 40Kg82Kg116Kg117Kg
GW (Kg) 42Kg95Kg132Kg133Kg
Quantity 20GP 360150120120
Quantity 40GP 600270195195
Quantity 40HQ 600270195195

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Specifications subject to the latest revision; need other technical documents? Ask our engineers.

Email Us WhatsApp