HF Series tower LiFePO4 battery, 14.3–32.2 kWh

A tall, narrow cabinet that stands against the wall — 14.3 kWh to 32.2 kWh at 51.2 V, with the 200 A current needed for a whole-house inverter.

HF Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Tower LiFePO4 battery, 51.2 V
Typical applications
Whole-home solar storage, small commercial backup, off-grid systems with high surge loads
Models in range
HF 51.2V280Ah, HF 51.2V314Ah, HF 51.2V412Ah, HF 51.2V560Ah, HF 51.2V628Ah
Category
Storage Batteries

The high-capacity single cabinet

Between 15 and 30 kWh, the choice is usually between stacking several small modules and buying one large cabinet. The HF takes the second route: a single tower, one BMS, one set of terminals, one breaker. Fewer connections means fewer failure points, and a service visit opens one cover rather than four.

The tower carries 280 Ah to 628 Ah cells at 51.2 V. The largest pair, 560 and 628 Ah, are 220 kg cabinets on castors — moving one across a garage floor is a two-person job with a pallet truck, not a lift.

Current, surge and inverter matching

200 A continuous at 51.2 V is just over 10 kW. That covers most whole-house inverters in the 5–10 kW class with headroom for surge. If the inverter is larger, parallel a second tower rather than pushing a single BMS beyond its rating — the BMS will derate on temperature before it trips, and a derated battery looks like a failing battery to the customer.

Thermal behaviour

LiFePO4 tolerates a wider temperature band than lead-acid, but the top of the charge curve is where heat matters. In a garage that reaches 35 °C in summer, mount the tower away from the inverter's exhaust and leave 100 mm behind the cabinet. The BMS reports cell temperature over CAN; if the inverter supports it, set the charge current to drop above 40 °C rather than waiting for the BMS to act.

Key Features

  • 51.2 V, 280 / 314 / 412 / 560 / 628 Ah — 14.3 to 32.2 kWh
  • 200 A continuous charge and discharge
  • LCD display with CAN and RS485 ports
  • Grade A cells, 8,000 cycles, 5-year warranty, 10+ year design life
  • Bluetooth and Wi-Fi monitoring standard
  • Wall-standing design, 286–326 mm deep
  • Optional smart BMS for third-party hybrid inverter protocols
  • Built-in over-charge, over-discharge, over-current, short-circuit and over-temperature protection

Applications

Whole-home backup

32.2 kWh covers a house with a heat pump through an evening and a cloudy morning without generator support.

High-surge off-grid

200 A at 51.2 V is 10 kW continuous — enough for a pump start on an off-grid property.

Small commercial storage

Two towers in parallel give 64 kWh for a shop or clinic, in a footprint smaller than a cabinet.

FAQ

How tall is the tower?
800 mm for the 280 and 314 Ah modules, 960 mm for the 412 Ah and 990 mm for the 560 and 628 Ah modules. All are under a metre, so they fit under a worktop or beside a door.
Does it need a plinth?
No, but it must stand on a level, load-bearing floor. Anchor the top to the wall where the site has seismic requirements or where children or trolleys pass.
Can I add capacity later?
Yes — parallel a second tower. Keep the DC cable lengths equal so the two towers share current evenly.
What is the difference from the HH vertical series?
The HF is a single tall cabinet with the largest cells; the HH covers a wider capacity spread in a slightly different case profile. Choose on footprint and capacity, not on technology — both use the same BMS family.

Specification reference

Parameter HF 51.2V280AhHF 51.2V314AhHF 51.2V412AhHF 51.2V560AhHF 51.2V628Ah
General
Case design Tower
Battery Type LiFePO4
Electrical
Normal Voltage(Vdc) 51.2V
Normal Capacity (25℃ 0.2C) (Ah) 280Ah314Ah412Ah560Ah628Ah
Normal Energy (25℃ 0.2C) (Wh) 14336Wh16076Wh21094Wh28672Wh32153Wh
Float Charge Voltage(Vdc) 56.0V
Operating Voltage Range (Vdc) 40.0~58.4V
Max. Charge Current(A) 200A
Max. Discharge Current(A) 200A
Terminal M8
Environment
Storage temperature 0 °C~30 °C
BMS & protection
IP degree IP 20
Storage duration 6 25 °C 6 months at 25 °C
Safety standard UN38.3,MSDS
Display LCD
Communication CAN, RS485, Bluetooth, WIFI
Protection Overcharge protection, Overdischarge protection, Overcurrent protection, Shortcircuit protection, Overtemperature protection
Environment
Working Temperature Charge 0 °C~+50 °C;Discharge -20 °C~+50 °C
Humidity 0~95%(no condensation)
Sea Level(m) 4000m (Derating above 2000m)
Mechanical & packing
LxWxH (products size, mm) 450*286*800 mm450*286*800 mm500*300*960 mm635*326*990mm635*326*990mm
LxWxH (package size, mm) 540*376*980 mm540*376*980 mm560*510*1090 mm695*525*1135mm695*525*1135mm
NW (Kg) 115Kg115Kg161Kg220Kg220Kg
GW (Kg) 130Kg130Kg180kg242Kg242Kg
Quantity 20GP 112112806060
Quantity 40GP 195195140104104
Quantity 40HQ 195195140104104

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Specifications subject to the latest revision; need other technical documents? Ask our engineers.

Email Us WhatsApp