All-in-one hybrid energy storage system, 7.2–15 kW

The grid-interactive end of the all-in-one range — 7.2 kW to 15 kW, 10 kWh to 32 kWh, with single-phase and three-phase 380 V variants and a generator input.

Hybrid ESS Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Hybrid all-in-one energy storage system, single- and three-phase
Typical applications
Residential with grid interaction, small commercial, three-phase farms and workshops
Models in range
ESS HX 7.2KW+10KWH, ESS HX 7.2KW+16KWH, ESS HX 7.2kW+10kWh, ESS HX 7.2kW+16kWh, ESS HX 12kW+16kWh, ESS HX 12kW+21kWh, ESS HX 12kW+32kWh, ESS LV 12kW+16kWh, ESS LV 12kW+21kWh, ESS LV 12kW+32kWh, ESS LV 15kW+21kWh, ESS LV 15kW+32kWh
Category
All-in-One ESS

Where the all-in-one range meets the grid

The hybrid variants add what a grid-interactive site needs: CT sensing at the service entrance, load management, generator input, and on the LV models, three-phase output at 380 V from a 48 V battery.

That last point is the unusual one. Most three-phase systems in this power class use a high-voltage battery; running 380 V output from 48 V keeps the battery in the same ecosystem as the single-phase cabinets and avoids a high-voltage safety regime on a residential site.

Single-phase and three-phase

The single-phase variants cover 7.2 kW and 12 kW, with 10 kWh to 32 kWh. The three-phase LV variants run 12 kW and 15 kW with 16–32 kWh, and supply unbalanced loads — which is what a farm or a workshop actually has.

Model range

Model Rated output Battery Variant
ESS HX 7.2KW+10KWH 7.2 KW 10 KWH 7.2 kW single-phase
ESS HX 7.2KW+16KWH 7.2 KW 16 KWH 7.2 kW single-phase
ESS HX 7.2kW+10kWh 7.2 kW 10 kWh 7.2 kW single-phase
ESS HX 7.2kW+16kWh 7.2 kW 16 kWh 7.2 kW single-phase
ESS HX 12kW+16kWh 12 kW 16 kWh 12 kW single-phase
ESS HX 12kW+21kWh 12 kW 21 kWh 12 kW single-phase
ESS HX 12kW+32kWh 12 kW 32 kWh 12 kW single-phase
ESS LV 12kW+16kWh 12 kW 16 kWh 12 kW three-phase LV
ESS LV 12kW+21kWh 12 kW 21 kWh 12 kW three-phase LV
ESS LV 12kW+32kWh 12 kW 32 kWh 12 kW three-phase LV
ESS LV 15kW+21kWh 15 kW 21 kWh 15 kW three-phase LV
ESS LV 15kW+32kWh 15 kW 32 kWh 15 kW three-phase LV
## Specifications by variant

12 kW single-phase

Parameter ESS HX 12kW+16kWh ESS HX 12kW+21kWh ESS HX 12kW+32kWh
PV Input Max. Input Capacity (kW) 15.6 — —
PV Input Max. Input Current (A) 26+26+26 — —
PV Input Short-circuit Current (A) 34+34+34 — —
Open Circuit Voltage (VDC) 500 — —
Start-up Voltage (VDC) 125 — —
MPPT Voltage (VDC) 150~425 — —
MPPT Full load Voltage (VDC) 300~425 — —
Rated Input/Output Active Power(kW) 12 — —
Max.Input/Output Apparent Power(VA) 13.2 — —
Input/Output Voltage Range (VAC) 220 / 230;L+N+PE — —
Rated AC Input/Output Current (A) 54.6/52.2 — —
Max AC Input/Output Current (A) 60/57.4 — —
Battery Mode Overload Capacity >200% for 10 sec — —
Input/Output Grid frequency Range (Hz) 50/60 — —
Output Power Factor(off grid) 0.8 leading to 0.8 lagging — —
Output Current Harmonic Distortion <3% (of nominal power) — —
Rated Input/Output Active Power(kW) 12 — —
Max.Input/Output Apparent Power(VA) 13.2 — —
Voltage (VAC) 220 / 230;L+N+PE — —
Rated AC Input Current (A) 54.6 — —
Frequency (Hz) 50/60 — —
Rated Input/Output Active Power(kW) 12 — —
Max.Input/Output Apparent Power(VA) 13.2 — —
Voltage (VAC) 220 / 230;L+N+PE — —
Rated AC Output Current (A) 52.2 — —
Frequency (Hz) 50 / 60 — —
Wave Form Pure Sine Wave — —
Nominal Voltage(VDC) 51.2VDC 51.2VDC 51.2VDC
Nominal Energy (kWh) 16.07(0.5C, 25 °C) 21.9(0.5C, 25 °C) 32(0.5C, 25 °C)
Usable Energy(90%DOD) 14.46kWh 18.98kWh 27kWh
Max. AC Charge Current (A) 250 — —
Max. PV Charge Current (A) 250 — —
Max Charge Current (PV+AC) (A) 250 — —
Max.Discharge Current (A) 250 — —
Operating Voltage Range 43.2Vdc~58.4Vdc — —
reveal LCD — —
Communication USB — —
Monitoring (optional) WiFi;4G (optional) — —
Ingress Protection IP65 — —
Operating Temperature Charge0 °C~+55 °C;Discharge-20 °C~+55 °C — —
Relative Humidity 5%~ 95% (Non-condensing) — —
Max Operating Altitude 4000m (Derating above 2000m) — —
LxWxH (products size, mm) 550x298x1280mm 550x298x1550mm 695x298x1550mm
LxWxH (package size, mm) 630x480x1360mm 630x480x1630mm 755x480x1630mm
Weight (NW Kg) 165 206 276
Weight (GW Kg) 187 244 314
Quantity 20GP 48 48 36
Quantity 40GP 96 96 82
Quantity 40HQ 120 105 82

12 kW three-phase LV

Parameter ESS LV 12kW+16kWh ESS LV 12kW+21kWh ESS LV 12kW+32kWh
PV Input Max. Input Capacity (kW) 15 — —
PV Input Max. Input Current (A) 36+18 — —
PV Input Short-circuit Current (A) 45+22.5 — —
Open Circuit Voltage (VDC) 1000 — —
MPPT Voltage (VDC) 200~800 — —
MPPT Full load Voltage (VDC) 350~800 — —
Rated Input/Output Active Power(kW) 12 — —
Max.Input/Output Apparent Power(kVA) 13.2 — —
Input/Output Voltage (VAC) 380/400(3W+N+PE) — —
Rated AC Input/Output Current (A) 21/20 — —
Battery Mode Overload Capacity >200% for 10 sec — —
Input/Output Grid frequency Range (Hz) 50/ 60 — —
Output Power Factor(off grid) 0.8 leading to 0.8 lagging — —
Output Current Harmonic Distortion <3% (of nominal power) — —
Rated Input/Output Active Power(kW) 12 — —
Max.Input/Output Apparent Power(VA) 13.2 — —
Voltage (VAC) 380/400(3W+N+PE) — —
Rated AC Input Current (A) 20 — —
Frequency (Hz) 50/ 60 — —
Rated Input/Output Active Power(kW) 12 — —
Max.Input/Output Apparent Power(VA) 13.2 — —
Voltage (VAC) 380/400(3W+N+PE) — —
Rated AC Output Current (A) 20 — —
Frequency (Hz) 50/ 60 — —
Wave Form Pure Sine Wave — —
Nominal Voltage(VDC) 51.2VDC 51.2VDC 51.2VDC
Nominal Energy (kWh) 16.07(0.5C, 25 °C) 21.09(0.5C, 25 °C) 32(0.5C, 25 °C)
Usable Energy(90%DOD) 14.46kWh 18.98kWh 27kWh
Max. AC Charge Current (A) 250 — —
Max. PV Charge Current (A) 250 — —
Max Charge Current (PV+AC) (A) 250 — —
Max.Discharge Current (A) 250 — —
Operating Voltage Range 43.2Vdc~58.4Vdc — —
reveal LCD — —
Communication USB — —
Monitoring (optional) WiFi;4G (optional) — —
Ingress Protection IP65 — —
Operating Temperature Charge0 °C~+55 °C;Discharge-20 °C~+55 °C — —
Relative Humidity 5%~ 95% (Non-condensing) — —
Max Operating Altitude 4000m (Derating above 2000m) — —
LxWxH (products size, mm) 550x298x1280mm 550x298x1550mm 695x298x1550mm
LxWxH (package size, mm) 630x480x1360mm 630x480x1630mm 755x480x1630mm
Weight (NW Kg) 175 216 276
Weight (GW Kg) 197 255 314
Quantity 20GP 48 48 36
Quantity 40GP 96 96 82
Quantity 40HQ 120 100 82

15 kW three-phase LV

Parameter ESS LV 15kW+21kWh ESS LV 15kW+32kWh
PV Input Max. Input Capacity (kW) 30 —
PV Input Max. Input Current (A) 36+20 —
PV Input Short-circuit Current (A) 45+25 —
Open Circuit Voltage (VDC) 1000 —
MPPT Voltage (VDC) 200~800 —
MPPT Full load Voltage (VDC) 350~800 —
Rated Input/Output Active Power(kW) 15 —
Max.Input/Output Apparent Power(kVA) 16.5 —
Input/Output Voltage (VAC) 380/400(3W+N+PE) —
Rated AC Input/Output Current (A) 25/22.7 —
Battery Mode Overload Capacity >200% for 10 sec —
Input/Output Grid frequency Range (Hz) 50/ 60 —
Output Power Factor(off grid) 0.8 leading to 0.8 lagging —
Output Current Harmonic Distortion <3% (of nominal power) —
Rated Input/Output Active Power(kW) 15 —
Max.Input/Output Apparent Power(VA) 16.5 —
Voltage (VAC) 380/400(3W+N+PE) —
Rated AC Input Current (A) 22.7 —
Frequency (Hz) 50/ 60 —
Rated Input/Output Active Power(kW) 15 —
Max.Input/Output Apparent Power(VA) 16.5 —
Voltage (VAC) 380/400(3W+N+PE) —
Rated AC Output Current (A) 22.7 —
Frequency (Hz) 50 / 60 —
Wave Form Pure Sine Wave —
Nominal Voltage(VDC) 51.2VDC 51.2VDC
Nominal Energy (kWh) 21.09(0.5C, 25 °C) 32(0.5C, 25 °C)
Usable Energy(90%DOD) 18.98kWh 27kWh
Max. AC Charge Current (A) 280 —
Max. PV Charge Current (A) 280 —
Max Charge Current (PV+AC) (A) 280 —
Max.Discharge Current (A) 280 —
Operating Voltage Range 43.2Vdc~58.4Vdc —
reveal LCD —
Communication USB —
Monitoring (optional) WiFi;4G (optional) —
Ingress Protection IP65 —
Operating Temperature Charge0 °C~+55 °C;Discharge-20 °C~+55 °C —
Relative Humidity 5%~ 95% (Non-condensing) —
Max Operating Altitude 4000m (Derating above 2000m) —
LxWxH (products size, mm) 550x298x1550mm 695x298x1550mm
LxWxH (package size, mm) 630x480x1610mm 755x480x1610mm
Weight (NW Kg) 216 276
Weight (GW Kg) 255 324
Quantity 20GP 44 40
Quantity 40GP 100 80
Quantity 40HQ 100 80

Key Features

  • 7.2 kW to 15 kW output; 10 kWh to 32 kWh battery
  • Single-phase 220/230 V and three-phase 380 V variants
  • Grid, generator and solar inputs on the same cabinet
  • Three-phase unbalanced output on the LV variants
  • Inverter, BMS and LiFePO4 battery integrated
  • 15.6 kW to 30 kW PV input on the larger variants
  • CT sensing and load management
  • App and cloud monitoring

Applications

Grid-interactive homes

Charge from PV, hold a reserve for backup, and shift load into the evening peak.

Farms and workshops

Three-phase 380 V output from a 48 V battery, with unbalanced load capability for real site conditions.

Small commercial

12–15 kW with 21–32 kWh covers a shop, guesthouse or clinic with generator backup.

FAQ

What makes it hybrid?
It accepts grid, generator and solar inputs and manages all three, rather than only charging from PV and discharging to load.
Do the three-phase variants need a high-voltage battery?
No — they run a 48 V battery, which is unusual in this power class and avoids a high-voltage stack.
Can it run without the grid?
Yes, with generator support on the AC input. The transfer is automatic on the backup output.
Which variant for a house?
7.2 kW single-phase with 10–16 kWh for most houses; 12 kW with 21–32 kWh where there is an EV or a heat pump and electric cooking.

Specification reference

Rated output7.2 kW to 15 kW
Battery capacity10 kWh to 32 kWh
Battery chemistryLiFePO4
Grid output220 / 230 V single-phase or 380 V three-phase
PV inputUp to 15.6 kW (single-phase) / 30 kW (three-phase)
InputsGrid, generator, solar
Load managementCT sensing and programmable windows

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Specifications subject to the latest revision; need other technical documents? Ask our engineers.

Email Us WhatsApp