EU-A Series single-phase hybrid inverter, 7.2 kW, IP66

A 7.2 kW single-phase hybrid in an IP66 enclosure, with two MPPTs, 10.5 kW of PV input and 160 A of charge current — for outdoor walls and markets where the inverter lives beside the meter.

EU-A Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Single-phase 220/230 V hybrid inverter, IP66
Typical applications
European residential solar, outdoor wall installation, generator-backup sites, smart-load self-consumption
Models in range
EU-A7200-48
Category
Solar Inverters

One model, done properly

The EU-A is a single-model series: 7.2 kW, 48 V battery, two MPPTs, IP66. That focus is deliberate. In the European residential market, 7 kW is the size that fits a heat-pump house, and the differences between a 6 kW and an 8 kW model are less important than whether the inverter can go outdoors and whether it can take two roof orientations.

Two MPPT channels at 10.5 kW total cover an east/west array, or a roof plus a garage array, without the losses of a single tracker. 160 A of charge current fills a 15 kWh battery in about four hours, which is the window a winter day actually offers.

IP66 in a residential setting

Most European houses put the meter cabinet on an outside wall, and the inverter follows it. IP66 removes the need for a plant room or a ventilated cabinet — but not the need to shade the unit. A dark enclosure in direct summer sun will derate; on a south wall, fit a hood or move to the north side.

Time windows and smart load

Six programmable charge and discharge windows let the inverter follow a time-of-use tariff rather than a fixed schedule. The smart-load output switches a heat pump or a water heater on when PV is surplus, which is often a better use of a midday peak than exporting at a low tariff.

Key Features

  • 7.2 kW output, 220/230 V single-phase, 48 V battery
  • IP66 enclosure — outdoor mounting without a cabinet
  • Two MPPT channels, up to 10.5 kW of PV
  • 160 A maximum charge and discharge current
  • Six configurable charge and discharge time periods
  • Generator input and smart-load output
  • Parallel up to 6 units
  • 0.8 leading to 0.8 lagging power factor on the off-grid output

Applications

European residential solar

7.2 kW covers a typical house with a heat pump, with 10.5 kW of PV split across two roof orientations.

Outdoor installations

IP66 means it can go on an outside wall beside the meter cabinet, cutting the DC and AC cable runs.

Time-of-use optimisation

Six charge windows let the battery fill at the cheap tariff and discharge into the evening peak.

FAQ

Why two MPPT channels?
East/west roofs and two array sizes produce different voltages; two trackers recover the mismatch that a single tracker would lose.
Can it run without a battery?
It can run PV-first with grid support, but the backup function and time-shifting require a battery.
Is IP66 enough outdoors?
Yes for rain and hose-down, not for direct sun. Mount on a north or east wall, or add a shade hood.
What battery does it expect?
48 V nominal LiFePO4, with the protocol loaded at the factory. Send the battery model at order confirmation.

Specification reference

Parameter EU-A7200-48
PV Input
Max. Input Power (kW) 10.5
Max. Input Current (A) 20+20
PV Input Short-circuit Current (A) 27+27
Open Circuit Voltage (VDC) 500
Start-up Voltage (VDC) 125
MPPT Voltage (VDC) 90~425
MPPT full load voltage (VDC) —
AC Input/ Output
Rated Input/Output Active Power(kW) 7.2
Max Input/Output Apparent Power(kVA) 7.2
Input/ Output Voltage Range (VAC) 220 / 230; 0.85Un~1.1Un; L+N+PE
Rated AC Input/Output Current (A) 32.7/31.3
Max AC Input/Output Current (A) 33
Battery Mode Overload Capacity >200% for 10 sec
Input/Output Grid frequency Range (Hz) 50±5 / 60±5
Output Power Factor(off grid) 0.8 leading to 0.8 lagging
Output Current Harmonic Distortion <3% (of nominal power)
Max.Parallel Quantity 6
Generator Input
Rated Input/Output Active Power(kW) 7.2
Max Input/Output Apparent Power(kVA) 7.2
Voltage (VAC) 220 / 230; L+N+PE
Rated AC Input Current (A) 31.3
Frequency (Hz) 50 / 60
AC Load Output(stand alone)
Rated Input/Output Active Power(kW) 7.2
Max Input/Output Apparent Power(kVA) 7.2
Voltage (VAC) 220 / 230; L+N+PE
Rated AC Output Current (A) 31.3
Frequency (Hz) 50 / 60
Output Wave Form Pure Sine Wave
Battery
Nominal Voltage(VDC) 48VDC
Max. AC Charge Current (A) 120
Max. PV Charge Current (A) 120
Max. Charge Current (PV + AC) (A) 120
Max.Discharge Current (A) 160
Operating Voltage Range 43.2Vdc~58.4Vdc
General Data
reveal LCD
communication USB
Monitoring (optional) WiFi; 4G (optional)
Ingress Protection IP66
Operating Temperature -10 °C~55 °C
Relative Humidity 5% ~ 95% (Non-condensing)
Max. Operating Altitude 4000m (Derating above 2000m)
DIMENSION
LxWxH (products size, mm) 473x377x219mm
LxWxH (package size, mm) 523x427x279mm
NW (Kg) 14
GW (Kg) 15.5
Quantity 20GP 350
Quantity 40GP 735
Quantity 40HQ 840

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Specifications subject to the latest revision; need other technical documents? Ask our engineers.

Email Us WhatsApp