EU-D Series single-phase hybrid inverter, 12 kW, 15.6 kW PV

Twelve kilowatts on a single phase, with 15.6 kW of PV input and the load management to keep a large house or a small business off the grid.

EU-D Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Single-phase 220/230 V hybrid inverter, 12 kW
Typical applications
Large residential, guesthouses, small commercial, sites with generator and ATS
Models in range
EU-D12000-48
Category
Solar Inverters

The largest single-phase model

Twelve kilowatts on one phase is a lot of current — 52 A at 230 V. That is the number to check first, because it decides whether the service entrance, the meter and the internal wiring can carry the inverter at full output. In most houses the answer is "yes, with export limiting", and the inverter is configured to hold import and export under the service rating.

With 15.6 kW of PV input, the EU-D is sized for a large array: a big roof, a ground mount, or a combination. The battery stays at 48 V, which keeps it in the same ecosystem as the rest of the range.

Commercial features in a residential box

ATS, CT sensing and load management are usually commercial features. Here they come as standard, because a 12 kW single-phase installation is usually a small business — a guesthouse, a clinic, a workshop — where the load has to be managed rather than assumed.

The six charge windows with cut-off thresholds let the site follow a commercial tariff: charge at night, hold through the morning, discharge into the afternoon peak, keep a reserve for backup.

Generators and bypass

Diesel generator compatibility plus mains bypass means the site can run from grid, battery or generator, in that order of preference, with the generator as the last resort rather than the default.

Key Features

  • 12 kW output on 220/230 V single phase, 48 V battery
  • 15.6 kW PV input for a large array
  • Up to 12 units in parallel for small commercial storage
  • Grid-to-off-grid switch under 10 ms
  • ATS, CT sensing and load management built in
  • Six charge windows with programmable cut-off thresholds
  • RS485, CAN and Wi-Fi onboard; 4G/GPRS optional
  • Mains bypass and mains charging, diesel generator compatible

Applications

Large residential

12 kW covers a house with a heat pump, an EV charger and a workshop on one phase.

Guesthouses and small hotels

Parallel units plus ATS keep the reception, lights and fridges running through an outage.

Small commercial storage

Up to 12 units parallel for peak shaving and backup in a shop, clinic or office.

FAQ

Can a single-phase supply take 12 kW?
At 230 V that is 52 A. Most European services are 40–63 A, so the inverter is usually set to limit export and grid import rather than run flat out.
What does the ATS do?
Switches the load between grid and inverter output automatically, which is what a small business needs when the grid fails and a generator is also on site.
Is 4G included?
Wi-Fi is standard; 4G/GPRS is an option for sites without a network — useful for a farm or a remote guesthouse.
How many units can be paralleled?
Up to 12 for commercial storage, with CT sensing on the service entrance for zero-export or export limiting.

Specification reference

Parameter EU-D12000-48
PV Input
Max. Input Power (kW) 15.6
Max. Input Current (A) 26+26+26
PV Input Short-circuit Current (A) 34+34+34
Open Circuit Voltage (VDC) 500
Start-up Voltage (VDC) 125
MPPT Voltage (VDC) 150-425
MPPT full load voltage (VDC) 300-425
AC Input/ Output
Rated Input/Output Active Power(kW) 12
Max Input/Output Apparent Power(kVA) 13.2
Input/ Output Voltage Range (VAC) 220 / 230; L+N+PE
Rated AC Input/Output Current (A) 54.6/52.2
Max AC Input/Output Current (A) 60/57.4
Battery Mode Overload Capacity >200% for 10 sec
Input/Output Grid frequency Range (Hz) 50/60
Output Power Factor(off grid) 0.8 leading to 0.8 lagging
Output Current Harmonic Distortion <3% (of nominal power)
Max.Parallel Quantity 6
Generator Input
Rated Input/Output Active Power(kW) 12
Max Input/Output Apparent Power(kVA) 13.2
Voltage (VAC) 220 / 230; L+N+PE
Rated AC Input Current (A) 54.6
Frequency (Hz) 50/60
AC Load Output(stand alone)
Rated Input/Output Active Power(kW) 12
Max Input/Output Apparent Power(kVA) 13.2
Voltage (VAC) 220 / 230; L+N+PE
Rated AC Output Current (A) 52.2
Frequency (Hz) 50 / 60
Output Wave Form Pure Sine Wave
Battery
Nominal Voltage(VDC) 48VDC
Max. AC Charge Current (A) 250
Max. PV Charge Current (A) 250
Max. Charge Current (PV + AC) (A) 250
Max.Discharge Current (A) 250
Operating Voltage Range 43.2Vdc~58.4Vdc
General Data
reveal LCD
communication USB
Monitoring (optional) WiFi; 4G (optional)
Ingress Protection IP66
Operating Temperature -10 °C~55 °C
Relative Humidity 5% ~ 95% (Non-condensing)
Max. Operating Altitude 4000m (Derating above 2000m)
DIMENSION
LxWxH (products size, mm) 630x435x259mm
LxWxH (package size, mm) 680x485x319mm
NW (Kg) 36
GW (Kg) 39
Quantity 20GP 198
Quantity 40GP 414
Quantity 40HQ 483

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Specifications subject to the latest revision; need other technical documents? Ask our engineers.

Email Us WhatsApp