INW Series grid-interactive hybrid inverter, 3.3–10.5 kW

The INV's grid-interactive sibling: IP54, feed-in to the grid, generator input, and the same 3.3–10.5 kW range for sites that sell power back.

INW Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Single-phase grid-interactive hybrid inverter, IP54
Typical applications
Grid-tied residential solar with backup, small commercial self-consumption, generator-hybrid sites
Models in range
IN 3600-24, INW 6500-48, INW 12000-48
Category
Solar Inverters

Export changes the design

Once an inverter can export, the utility's requirements arrive with it: a grid code, an anti-islanding test, a power factor setting, and often a limit on export current. The INW carries those settings in firmware, selected at commissioning from a country list.

Mechanically, the INW is the outdoor-rated version of the INV platform — IP54 instead of an open chassis, with a sealed cable entry and a UV-stable cover. That lets it mount on an outside wall next to the array rather than in a plant room.

Generator hybrid

On sites with a diesel generator, the INW uses the generator as a charge source rather than a permanent supply: the generator runs at its efficient point to charge the battery, then stops, and the inverter supplies the load from the battery. That cycle typically cuts fuel use by 30–50 % against continuous generator running, and it cuts engine hours, which is the larger maintenance cost.

Parallel and phase balance

Up to nine units parallel on one phase. On a single-phase supply that is usually done for capacity, but it is also done for resilience: three units in parallel, one fails, the site keeps running at reduced capacity.

Key Features

  • 3.3 kW to 10.5 kW, 24 V and 48 V battery
  • Grid feed-in as well as self-consumption
  • IP54 enclosure for semi-outdoor installation
  • Built-in 100 A MPPT solar charger, 40–450 V window
  • Generator input, with programmable charge current
  • Parallel up to 9 units
  • Dual AC output and LCD display
  • Wi-Fi monitoring, lithium battery activation

Applications

Residential self-consumption with export

Runs the house from PV first, charges the battery, then exports the surplus under the local feed-in tariff.

Generator-hybrid sites

Accepts a diesel generator on the AC input, reducing generator hours by cycling the battery instead.

Small commercial

Three units in parallel cover a shop or workshop with three-phase-ish loads on single-phase supply.

FAQ

What is the difference from the INV series?
The INW can export to the grid and carries an IP54 rating. The INV is off-grid only and IP20-class. Choose INW where a feed-in tariff or outdoor siting applies.
Can it export without a battery?
It can run PV-first without a battery in some configurations, but the backup function requires one. Confirm the grid code requirement for battery-less operation before designing.
Does it work with a generator?
Yes — generator input with adjustable charge current, which is the usual way to cut diesel run-hours on a remote site.
How is the grid code set?
At commissioning, from the display or the app, from a list of country codes. Setting the wrong code is the most common cause of export refusal.

Specification reference

Parameter IN 3600-24INW 6500-48INW 12000-48
PV Input
Max. Input Power (kW) 591MPPT:9KW; 2MPPT:7.5KW+7.5KW
Max. Input Current (A) 18271MPPT:27A; 2MPPT:22.5A+22.5A
PV Input Short-circuit Current (A) 223333
Open Circuit Voltage (VDC) 500
Start-up Voltage (VDC) 608080
MPPT Voltage (VDC) 40~45060~45060~450
AC Input
Rated Input Voltage (VAC) 208 / 220 / 230 / 240; L+N+PE
Voltage Range (VAC) 90-280±3V(Normal) / 170-280±3V(UPS)
Frequency (Hz) 50 / 60
Max. Bypass Input Current (A) 204070
Parallel Quantity NA9 Max. 9-unit parallel operation6 Max. 6-unit parallel operation
AC Output
Rated Capacity (kW) 3.66.512
Output Power (battery mode) (kW) 3.36.510.5
Voltage (VAC) 208 / 220 / 230 / 240
Frequency (Hz) 50/60Hz±0.1%
Output Wave Form Pure Sine Wave
Battery Mode Overload Capacity 60s @ 102%-120% Load; 10s @ 120%-200% Load
Battery Mode Max. Efficiency 92.7%@24VDC93%@48VDC94%@48VDC
Switch Time (ms) <10
Battery
Nominal Voltage(VDC) 244848
Max. AC Charge Current (A) 100120160
Max. PV Charge Current (A) 100120160
Max. Charge Current (PV + AC) (A) 100120160
Max.Discharge Current (A) 160160220
Operating Voltage Range (VDC) 21.6Vdc~29.2Vdc43.2Vdc~58.4Vdc43.2Vdc~58.4Vdc
General Data
Reveal LCD
Communication RS485 /CAN / USB
Monitoring WIFI/4G (Optional)
Ingress Protection IP54
Operating Temperature -10 °C~55 °C
Relative Humidity 5% ~ 95% (Non-condensing)
Max. Operating Altitude 4000m (Derating above 2000m)
DIMENSION
NW (Kg) 6.18.314.2
GW (Kg) 7.29.515.7
Products Size(W*H*D)mm L420xW289xH100L410xW331xH135L495xW425xH132
Package Size(W*H*D)mm L500xW369xH170L472xW405xH210L551xW491xH191
Quantity 20GP 560440360
Quantity 40GP 1240960750
Quantity 40HQ 161213201000

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Specifications subject to the latest revision; need other technical documents? Ask our engineers.

Email Us WhatsApp