TP LV-A Series three-phase hybrid inverter, 12–15 kW, 48 V battery

Three-phase output from a 48 V battery — 12 kW and 15 kW, with unbalanced load capability, 250 A of charge current and an IP66 enclosure.

TP LV-A Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Three-phase 380/400 V hybrid inverter, 48 V battery
Typical applications
Three-phase residential, small commercial and agricultural sites, workshops with 3-phase motors
Models in range
TP LV-A12000, TP LV-A15000
Category
Solar Inverters

Three-phase without a high-voltage battery

Most three-phase hybrid inverters in this power class expect a high-voltage battery — 100 V to 800 V — which means a stack, a high-voltage BMS and a different safety regime. The TP LV-A takes a 48 V battery instead, which keeps it in the same ecosystem as the single-phase range.

The trade-off is current. At 48 V, 12 kW is 250 A, which is why the charge and discharge rating is 250 A and why the DC cable is heavier than a high-voltage equivalent. In exchange, the installer is working with a battery they already know.

Unbalanced output

Real three-phase installations are not balanced: one phase carries the lights, another the heat pump, a third the workshop. An inverter that insists on balanced output either trips or derates. The TP LV-A supplies each phase independently within its limit, which is the behaviour a farm or a workshop actually needs.

PV and generator

Two MPPT channels take 15 kW or 30 kW of PV depending on model, and the generator input covers the winter weeks when the array cannot keep up. Six charge windows let the site use a time-of-use tariff where one exists.

Key Features

  • 12 kW and 15 kW three-phase output, 380/400 V, 3W+N+PE
  • 48 V battery — no high-voltage battery stack required
  • Unbalanced output across the three phases
  • 250 A maximum charge and discharge current
  • Two MPPT channels, 15 kW and 30 kW PV input
  • IP66 enclosure for outdoor installation
  • Six configurable charge and discharge windows
  • Generator input and smart-load support

Applications

Three-phase houses

A house with a three-phase supply and a heat pump gets balanced output without a high-voltage battery.

Workshops and farms

Three-phase motors, welders and pumps run directly from the inverter, with the battery covering peak demand.

Small commercial

Up to 6 units parallel for 72–90 kW, with unbalanced output matching real single-phase loads.

FAQ

Why a 48 V battery on a three-phase inverter?
It avoids a high-voltage battery stack, which lowers the cost and keeps the battery in the same ecosystem as the single-phase models. The trade-off is current: 250 A at 48 V is about 12 kW.
Does it support unbalanced loads?
Yes — the three phases can carry different loads, which is what real installations have. Confirm the maximum imbalance in the manual before designing.
Can it export three-phase?
Yes, with the grid code set at commissioning. Export limiting is configured per phase where the utility requires it.
What PV input does the 15 kW model take?
Up to 30 kW across two MPPT channels, which suits a large agricultural roof or a ground mount.

Specification reference

Parameter TP LV-A12000TP LV-A15000
PV Input
Max. Input Power (kW) 1530
Max. Input Current (A) 36+1836+20
PV Input Short-circuit Current (A) 45+22.545+25
Open Circuit Voltage (VDC) 1000
Start-up Voltage (VDC) —
MPPT Voltage (VDC) 200~800
MPPT full load voltage (VDC) 350~800
AC Input/ Output
Rated Input/Output Active Power(kW) 1215
Max Input/Output Apparent Power(kVA) 13.216.5
Input/ Output Voltage Range (VAC) 380/400(3W+N+PE)
Rated AC Input/Output Current (A) 21/2025/22.7
Max AC Input/Output Current (A) —
Battery Mode Overload Capacity >200% for 10 sec
Input/Output Grid frequency Range (Hz) 50 / 60
Output Power Factor(off grid) 0.8 leading to 0.8 lagging
Output Current Harmonic Distortion <3% (of nominal power)
Max.Parallel Quantity 6
Generator Input
Rated Input/Output Active Power(kW) 1215
Max Input/Output Apparent Power(kVA) 13.216.5
Voltage (VAC) 380/400(3W+N+PE)
Rated AC Input Current (A) 2022.7
Frequency (Hz) 50 / 60
AC Load Output(stand alone)
Rated Input/Output Active Power(kW) 1215
Max Input/Output Apparent Power(kVA) 13.216.5
Voltage (VAC) 380/400(3W+N+PE)
Rated AC Output Current (A) 2022.7
Frequency (Hz) 50 / 60
Output Wave Form Pure Sine Wave
Battery
Nominal Voltage(VDC) 48VDC
Max. AC Charge Current (A) 250280
Max. PV Charge Current (A) 250280
Max. Charge Current (PV + AC) (A) 250280
Max.Discharge Current (A) 250280
Operating Voltage Range 43.2Vdc~58.4Vdc
General Data
reveal LCD
communication USB
Monitoring (optional) WiFi; 4G (optional)
Ingress Protection IP66
Operating Temperature -10 °C~55 °C
Relative Humidity 5% ~ 95% (Non-condensing)
Max. Operating Altitude 4000m (Derating above 2000m)
DIMENSION
LxWxH (products size, mm) 658x475x258mm683x475x265mm
LxWxH (package size, mm) 763x540x370mm955x695x470mm
NW (Kg) 3840
GW (Kg) 4549
Quantity 20GP 14068
Quantity 40GP 300144
Quantity 40HQ 360180

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Specifications subject to the latest revision; need other technical documents? Ask our engineers.

Email Us WhatsApp