Data centers demand the highest levels of power reliability. This FAQ covers High Idea Power’s E Series, ET Series, and ETPRO Series rack-mount UPS solutions — from small server rooms to enterprise-scale three-phase deployments with N+1 redundancy.

1. What UPS topology is best for data centers?

Online double-conversion is the industry standard. Unlike standby UPS, online units continuously convert AC to DC and back to clean AC, providing zero transfer time and complete isolation from grid disturbances.

Series Capacity Form Factor Battery
ET1K 1000VA/800W Tower Built-in LiFePO4 36V 15AH
ET3K 3000VA/2400W Tower Built-in LiFePO4 48V 30AH
E1KS-48 1000VA/800W 1U Rackmount External 48V battery
E2KS-48 2000VA/1600W 1U Rackmount External 48V battery
E3KS-48 3000VA/2400W 1U Rackmount External 48V battery
ETPRO 30-60KS 30–60KVA Rackmount External LiFePO4

2. What is N+1 redundancy and how do I configure it?

N+1 redundancy installs one more UPS module than the minimum required. If any single module fails, remaining modules continue without interruption. The ETPRO 30–60KS supports parallel operation of up to 3 units. A 30KW load would use 2 × ETPRO 40KS in parallel — each capable of 40KVA, only 30KW needed. Parallel connection requires communication cable and current-sharing cable between units.

3. How efficient are High Idea Power data center UPS systems?

E and ET Series achieve >90% efficiency in double-conversion mode. ETPRO supports ECO mode up to 98% efficiency by bypassing the double-conversion circuit when input quality is good. The inverter stays synchronized and ready to switch back within milliseconds. Note: ECO mode is not supported in parallel configurations.

4. What cooling and ventilation do rackmount UPS units require?

  • Maintain at least 100mm clearance at front and rear for airflow.
  • Ambient temperature: 0–40°C. For every 10°C above 25°C, battery life decreases ~50%.
  • Humidity: 0–90% non-condensing.
  • ETPRO uses forced-air cooling with temperature-controlled fans.

5. Tower vs. rackmount — which for my data center?

For data centers with standard 42U racks, the 1U E Series (E1KS-48, E2KS-48, E3KS-48) maximizes equipment density. For larger facilities, ETPRO 30–60KS provides three-phase 400V output at industrial scale. Tower models (ET1K, ET3K) suit small server rooms with floor/shelf placement.

6. What battery configuration gives longest runtime?

Battery Pack Capacity Runtime (E3KS-48 at 2000W)
LD4810 48V 10AH ~12 minutes
LD4820 48V 20AH ~25 minutes
LD4830 48V 30AH ~38 minutes
LD4850 48V 50AH ~60 minutes

7. Can I monitor data center UPS status remotely?

Yes. All E and ETPRO units include RS-232 and USB ports plus an intelligent card slot for SNMP/network cards. Features: real-time web monitoring, email/SMS alerts, scheduled self-tests, remote shutdown, and NMS integration. ETPRO adds dry contacts for BMS and EPO circuits.