Power & Telecom Inverters
DC bus in, clean isolated AC out — inverter systems for sites where the primary source is a station battery or telecom DC panel, not the utility grid.
HighIdea Power & Telecom Inverters convert a DC bus into clean, galvanically isolated AC. They are built for sites where the primary source is a battery bank or a station DC panel rather than the utility grid: substations and power plants, telecom base stations, railway signalling, HVDC data rooms, RTU/SCADA cabinets and industrial control panels.
These are not solar inverters. Solar (PV) inverters in the Solar Inverters range are designed around an MPPT charger and a PV array; power and telecom inverters are designed around a DC bus, strict AC/DC isolation, no back-feed noise into the DC system and zero or near-zero transfer time. Where the site needs an AC-input UPS with its own battery instead, see UPS Power Supply.
The range is split by operating principle:
- Online DC-AC Inverters — full double conversion, 0 ms transfer and continuous inverter-fed output. H 1-3kVA, H 6-20k, HM 3-15kVA, HP 6k and HT 1-20k.
- Standby & Offline Inverters — AC-priority or DC-priority operation with a fast transfer, higher efficiency and a lower cost where a brief switch is acceptable. HB 5/10k and HTB 1-12kVA.
Specifying a unit. Confirm the DC bus voltage first (12 / 24 / 36 / 48 / 60 / 72 / 110 / 220 / 240VDC or a wide 160-300VDC window), then the required kVA and kW, the output voltage and frequency (220 / 230 / 240Vac, 50 or 60Hz), the acceptable transfer time, and whether galvanic isolation or an external isolation transformer is mandated. Also state the battery chemistry, the required autonomy and the communication protocol (RS485 / SNMP / Modbus) for the site monitoring system.
All models are built in our own factory and support OEM/ODM customization of capacity, DC input voltage, output voltage, enclosure format, communication protocol and branding. Pair them with LiFePO4 battery packs or a conventional VRLA string sized to the site's autonomy requirement.
Sub-categories2 ranges
Online DC-AC Inverters
Online double-conversion DC-AC inverters, 1-20kVA, with 0 ms transfer, full AC/DC isolation and no back-feed noise for power and telecom DC buses.
5 series — selection guide →Standby & Offline Inverters
Standby / offline DC-AC inverters with AC-priority or DC-priority modes, 8-10 ms transfer and high efficiency for telecom, power and railway backup.
2 series — selection guide →Online DC-AC Inverters5 series
| Model | Type | Typical applications | Notes |
|---|---|---|---|
H Series 1-3kVA
|
Online double-conversion DC-AC inverter (rack-mount) | Substations, power plants, telecom base stations, HVDC data rooms, NAS and control equipment | DC input voltage is fixed per order — 24, 48, 110, 220 or 240VDC |
H Series 6-20k
|
Online double-conversion DC-AC inverter with external isolation transformers | Power plants, HVDC equipment rooms, utility DC panels, integrated AC/DC power systems | External input and output power-frequency isolation transformers are specified separately |
HM Series 3-15kVA
|
Modular parallel DC-AC inverter (48VDC, 19-inch rack) | Telecom equipment rooms, modular IT rooms, industrial control, security systems, office backup | Standard configuration uses up to five 3kVA modules; battery bank is external |
HP Series 6k
|
CPU-controlled PWM DC-AC inverter (24 / 48VDC) | Telecom cabinets, equipment rooms, field and portable power installations | Available as a 19-inch rack unit or in a portable transport case |
HT Series 1-20k
|
Power-frequency online double-conversion inverter (rack-mount) | Power plants, substations, distribution rooms, power-line carrier, RTU and SCADA systems | Designed to operate from the station DC panel / battery bank; isolation transformer built in |
Standby & Offline Inverters2 series
| Model | Type | Typical applications | Notes |
|---|---|---|---|
HB5/10K-48/110/220/240(A)
|
Standby / offline DC-AC inverter with DSP control (rack-mount) | Substations, telecom equipment rooms, base stations, HVDC systems, wind power | AC-priority and DC-priority modes are selectable; DC input voltage fixed per order |
HTB 1-12kVA
|
Standby power-frequency DC-AC inverter with battery charging | Telecom, railway signalling, power and industrial backup, commercial and residential standby | DC input versions from 12 to 72VDC; three-stage charging for lead-acid, lithium and solid-state batteries |
Models with links have detailed specification pages; unlisted models are also available on request. Capacity and quantity should be sized by our engineers against the actual load — never by nameplate rating alone.
Power & Telecom Inverters — frequently asked questions
How is this different from a solar inverter?
What is the difference between online and standby models?
Which DC bus voltages are supported?
Do these replace a UPS?
Other product lines
Every HighIdea range has its own category page with sub-categories, model tables and a selection guide.
UPS Power Supply
Online, offline, lithium, three-phase high-frequency and transformer-isolated industrial UPS from 500VA to 600kVA — tower and rack, plus 100/110/120V low-voltage models for global markets.
View category →Switching Power Supplies & Rectifiers
19-inch AC-DC rectifiers, embedded telecom power systems and DC-DC converters that deliver stable 24 / 48 / 110 / 220VDC to base stations, DC panels, substations and industrial control cabinets.
View category →Solar Inverters
Single-phase and three-phase hybrid inverters from 1.2 kW to 15 kW — off-grid, grid-interactive, split-phase 120/240 V and 380 V three-phase, on 12 V to 48 V batteries.
View category →Storage Batteries
LiFePO4 battery modules from 1.28 kWh to 32.2 kWh in seven form factors — wall-mounted, stacked, 19-inch rack, lead-acid replacement, tower, vertical and IP65 floor-standing.
View category →All-in-One ESS
Inverter, BMS and LiFePO4 battery in one cabinet — 300 W portable packs through 15 kW three-phase systems, 896 Wh to 32 kWh, for the EU, US and export markets.
View category →Accessories & BMS
SNMP cloud monitoring cards, smart BMS boards and matched LiFePO4 chargers — the parts that decide whether a system reports honestly and reaches its rated cycle life.
View category →Portable Power Stations
Sealed and rugged portable power stations, 1.0 kWh to 16.08 kWh and 1.2 kW to 5 kW, with LiFePO4 cells, pure sine inverters, MPPT solar input and 10 ms UPS transfer for field, commercial backup and off-grid use.
View category →