GX Series Industrial-Frequency UPS, 6–600kVA
The heavy-industry standard — transformer-isolated, overload-brutal, built for power plants, substations, steel and mining from 6 to 600kVA.
Product image
- Brand
- HighIdea
- Type
- Industrial-frequency online UPS (transformer-isolated)
- Typical applications
- Power plants, substations, steel, mining, chemical plants
- Models in range
- GX(A) 6–120 kVA (220/230/240 Vac), GX(A) 6–120 kVA LV (100/110/120 Vac), GX33 10–600 kVA
- Category
- Industrial UPS
When the protected process is a power plant, a substation or a steel line, the UPS is specified for worst-case electrical abuse — and that is exactly what the GX series is engineered to deliver: power-frequency online conversion behind an isolation transformer, with overload, surge and interference tolerance that high-frequency designs cannot match. Capacities from 6kVA single units to 600kVA systems, in high-voltage (220–240Vac) and low-voltage (100–120Vac) output versions.
Key Features
- Power-frequency topology with isolation-transformer output — galvanic separation and brutal overload tolerance
- Wide range: 6kVA single units up to 600kVA systems
- LV versions with 100/110/120Vac output for low-voltage industrial sites
- High anti-interference, lightning protection and surge resistance
- Strong overload capacity for inrush-heavy industrial loads
- Engineered for electric-power environments: wide input window, generator and DC-system compatibility
Specifications
| Capacity | 6 – 600 kVA |
|---|---|
| Topology | Industrial (power) frequency |
| Output voltage | 220 / 230 / 240 Vac or 100 / 110 / 120 Vac versions |
| Isolation | Output isolation transformer |
| Overload capacity | High (transformer design) |
| Protection | Lightning / surge / anti-interference design |
| Communication | RS-232 / SNMP / Modbus options |
Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.
Applications
Power plants & substations
Relay protection, control and communication systems demand the robustness only power-frequency designs guarantee.
Steel, mining & chemical
Inrush-heavy loads and dirty supply stop high-frequency UPS; the GX shrugs them off.
Low-voltage industrial sites
LV versions deliver 100–120Vac output for sites standardized on low-voltage control power.
FAQ
Why choose power-frequency over high-frequency?
What is the largest configuration?
Related Models
EX33 Series
High-frequency three-phase online protection in a tower cabinet — 10 to 80kVA for data centers and critical infrastructure.
View detailsHT Series
Rack-format power-frequency UPS engineered for power plants, substations and communication front-end power — dual-conversion online, zero switching.
View details