ET1-3K Tower Online UPS with Built-in LiFePO4

Online double-conversion tower UPS with a Class A LiFePO4 battery inside — 30 minutes of full-load backup (23 minutes on ET3K) in one cabinet, maintenance-free.

ET1-3K Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Online double-conversion UPS (tower)
Typical applications
Servers, workstations, medical devices, labs, network core equipment
Models in range
ET1K, ET2K, ET3K
Category
UPS Power Supply

The ET1-3K series is the flagship of HighIdea's lithium UPS line: a true online double-conversion UPS with a Class A LiFePO4 battery integrated in the tower cabinet. Where a lead-acid system needs an external battery rack to reach 30 minutes of full-load backup, the ET1-3K does it in a single box roughly one-third the size.

The battery management system is engineered for high-current charging and full cell balancing, eliminating the low-current protection shutdowns that affect generic lithium conversions. All cells are new-production Class A — never second-life cells.

Key Features

  • Built-in Class A LiFePO4 battery — 460.8 Wh (ET1K) to 1,228.8 Wh (ET3K), 1,200+ cycles, 10+ years float-charge life
  • True online double conversion with zero-millisecond transfer between mains, battery and bypass
  • Full-load backup without external battery cabinets — 30 minutes on ET1K/ET2K, 23 minutes on ET3K
  • DSP digital control with high-frequency PWM for stable, precise output
  • Wide input range (172–268 VAC) with three/four-level lightning protection for harsh grids
  • Active input power factor correction (PFC) — clean to the grid, low operating cost
  • Output voltage selectable 220/230/240Vac, auto-adapting 50/60Hz
  • Automatic power-on after outage recovery — suitable for unattended sites
  • RS-232 standard; optional SNMP/Modbus/dry contacts and cloud IoT monitoring

Applications

Office servers & workstations

One tower unit keeps the server, switch and workstations alive through outages — no separate battery cabinet needed.

Medical & laboratory equipment

Zero-transfer online protection for devices that cannot tolerate any interruption or waveform distortion.

Unattended & remote sites

Automatic power-on after recovery and cloud monitoring support make it fit for base stations and remote rooms.

FAQ

How long does it run at full load?
ET1K and ET2K hold 30 minutes at 100% load; ET3K holds 23 minutes at full load and 42 minutes at half load. At lower loads runtime extends further.
Is the battery replaceable or maintenance-free?
The battery is maintenance-free for its service life (1,200+ cycles / 10+ years float). Replacement is possible but rarely needed within the normal lifecycle.
Can the output voltage be set to my market standard?
Yes — 220/230/240Vac selectable at setup, with automatic 50/60Hz adaptation. For 100–127V markets see the D1 series.

Related Models

Specification reference

Parameter ET1KET2KET3K
General
Rated output capacity 1,000 VA / 900 W2,000 VA / 1,800 W3,000 VA / 2,700 W
Working mode Online double conversion
Control DSP digital control + high-frequency PWM
Form factor Tower
AC input
Nominal voltage 220 VAC (230 / 240 VAC selectable)
Nominal frequency 50/60 Hz auto-sensing
Input voltage range 172–268 VAC (±7 VAC)
Input frequency range 45–55 Hz / 55–65 Hz (±0.5 Hz)
Battery
Nominal battery voltage 24 V48 V48 V
Cell type Class A LiFePO4
Cell string 8S16S16S
Built-in capacity 460.8 Wh921.6 Wh1,228.8 Wh
Battery life Float life 10+ years; 1,200+ cycles
Cell protection Per-cell over-charge, over-discharge, imbalance, over-current, short-circuit
Cell balancing Yes
Fuel-gauge management Yes
Low-voltage alarm / shutdown 22 V / 21–30 V44 V / 42–60 V44 V / 42–60 V
Charge voltage 28.8 ±0.2 V57 ±0.3 V57 ±0.3 V
Charge current 2 A3 A3 A
Charging method Constant current, then constant voltage
Recharge time 8–10 h to 90%
Backup time 50 min half load / 30 min full load50 min half load / 30 min full load42 min half load / 23 min full load
AC output
Output voltage 220 VAC ±3% (230 / 240 VAC selectable)
Output frequency 50/60 Hz ±5 Hz on mains; ±1% on battery
Dynamic voltage transient <5%
Transient recovery time <60 ms
Waveform Pure sine wave; THD <3% linear, <8% non-linear
Output power factor 0.8
Overload capacity 130% ≥20 s on mains; 120% ≥20 s on battery
Peak current factor 3:1
Transfer time (mains ↔ battery) 0 ms
Transfer time (inverter ↔ bypass) <4 ms
Communication & protection
Communication RS-232 standard; optional RS-485 (Modbus), dry contacts, SNMP
Protection Battery over/under-voltage, overload, over-temperature, short circuit, output over/under-voltage
Mechanical
Net weight 8.6 kg19.6 kg22 kg
Net dimensions (W × H × D) 145 × 220 × 355 mm190 × 318 × 433 mm190 × 318 × 433 mm
Packaging dimensions (W × H × D) 442 × 251 × 363 mm560 × 340 × 485 mm560 × 340 × 485 mm
Environment
Operating temperature −10 °C to +40 °C
Operating humidity 20–90% RH, non-condensing
Altitude No derating below 1,000 m; −1% per 100 m above

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.