ET1-6KRS Online Rack Lithium Battery UPS

1–6kVA online rack platform with modular lithium battery selection — choose the runtime by choosing the packs.

ET1-6KRS Series Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Online double-conversion UPS (rack)
Typical applications
Server racks, data centers, telecom equipment, industrial control
Models in range
ET1KRS, ET2KRS, ET3KRS, ET6KRS
Category
UPS Power Supply

The ET1-6KRS is the flexible middle of the ET rack line: the UPS chassis and the lithium battery packs are separate, so runtime is a configuration choice rather than a chassis constraint. Pair one 6kVA unit with two packs for compact sites, or more packs when the load profile demands longer autonomy.

Key Features

  • Online double conversion with pure sine wave output and 0 ms transfer
  • Modular battery selection — external 48V LiFePO4 packs, 15S or 16S (15S factory default)
  • DSP-controlled high-frequency conversion for high efficiency
  • Wide input window 172–268 VAC with generator compatibility
  • LCD status display with battery health and runtime estimation
  • SNMP / Modbus / dry-contact options and cloud monitoring support

Applications

Growing server rooms

Start with one pack per UPS and add capacity as the load grows — no forklift upgrade needed.

Telecom equipment rooms

Rack format and remote monitoring suit sheltered and unattended telecom sites.

FAQ

Which battery packs work with it?
The platform accepts 48V LiFePO4 packs with standard BMS communication — HighIdea LD48V packs are the plug-and-play choice, and major third-party 48V packs are compatible.
What is the difference to the ET1-3KR?
The ET1-3KR has the battery built in; the ET1-6KRS uses external modular packs, giving you free choice of runtime and capacity up to 6kVA.

Related Models

Specification reference

Parameter ET1KRSET2KRSET3KRSET6KRS
General
Rated output capacity 1,000 VA / 900 W2,000 VA / 1,800 W3,000 VA / 2,700 W6,000 VA / 5,400 W
Working mode Online double conversion
Control DSP digital control + high-frequency PWM
Form factor 19-inch rack, 2U
AC input
Nominal voltage 220 VAC (230 / 240 VAC selectable)
Nominal frequency 50/60 Hz auto-sensing
Input voltage range 172–268 VAC (±7 VAC)
Input frequency range 45–55 Hz / 55–65 Hz (±0.5 Hz)
Battery (external)
Nominal battery voltage 48 V
Cell type Class A LiFePO4
Cell string requirement 15S / 16S (15S factory default)
External pack capacity required >10 Ah>20 Ah>30 Ah>50 Ah
Battery life Float life 10+ years; 1,200+ cycles
Cell protection Provided by the external pack BMS
Cell balancing Provided by the external pack BMS
Fuel-gauge management Configured to the installed pack
Low-voltage alarm / shutdown 44 V / 42–60 V
Charge voltage 54 ±0.3 V
Charge current 5 A5 A5 A5 A default, expandable to 10–30 A
Charging method Constant current, then constant voltage
Backup time Determined by the connected pack capacity
AC output
Output voltage 220 VAC ±3% (230 / 240 VAC selectable)
Output frequency 50/60 Hz ±5 Hz on mains; ±1% on battery
Dynamic voltage transient <5%
Transient recovery time <60 ms
Waveform Pure sine wave; THD <3% linear, <8% non-linear
Output power factor 0.8
Overload capacity 130% ≥20 s on mains; 120% ≥20 s on battery
Peak current factor 3:1
Transfer time (mains ↔ battery) 0 ms
Transfer time (inverter ↔ bypass) <4 ms
Communication & protection
Communication RS-232 standard; optional RS-485 (Modbus), dry contacts, SNMP
Protection Battery over/under-voltage, overload, over-temperature, short circuit, output over/under-voltage
Mechanical
Net weight 6.5 kg9.5 kg10 kg14 kg
Net dimensions (W × H × D) 440 × 88 × 310 mm440 × 88 × 440 mm440 × 88 × 440 mm440 × 88 × 500 mm
Packaging dimensions (W × H × D) 538 × 190 × 402 mm538 × 168 × 538 mm538 × 168 × 538 mm538 × 168 × 600 mm
Environment
Operating humidity 20–90% RH, non-condensing
Altitude No derating below 1,000 m; −1% per 100 m above
Storage temperature −40 °C to +45 °C
Storage humidity 20–90% RH, non-condensing

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.