EPS-D Series Rolling Door UPS, 600 W-6 kW
Emergency power built for a motor, not a server: pure sine wave output, high motor-starting capacity and an integrated battery pack that keeps a rolling shutter, garage door or industrial gate working through a mains failure.
Product image
- Brand
- HighIdea
- Type
- Rolling door / shutter motor emergency power supply (EPS) with built-in VRLA batteries
- Typical applications
- Roller shutters, garage doors, high-speed and fast doors, sliding and retractable gates, bank and factory access doors
- Models in range
- EPS 6D, EPS 7D, EPS 12D, EPS 20D, EPS 30D, EPS 50D
- Category
- UPS Power Supply
A rolling door that cannot open is a blocked loading bay, a locked shopfront or a trapped vehicle. The EPS-D series is an emergency power supply built specifically around that problem: a pure sine wave inverter, built-in batteries and microprocessor control in a compact steel enclosure, with enough short-term overload capacity to start a motor rather than just keep a router alive.
Where it fits
Use it on roller shutters and garage doors, tubular and translation-door motors, high-speed fast doors, retractable expansion gates, industrial sliding gates and flap-gate motors — the loads a general IT UPS is not designed to start. Single-phase 6D/7D/12D/20D wall-mount units suit individual doors and small premises; the 30D/50D three-phase cabinets serve door banks in factories, logistics centres and multi-bay car parks. Boost and buck AVR plus a wide input window (160-270 Vac single phase, 330-415 Vac three phase) keep it working on the unstable supplies common at these sites.
Sizing and selection
Start with the motor's rated power and starting current, not the door width. The catalogue maps the family to door classes from 0.6 T to 3 T and lists two output-power rows per model — continuous rated output (600-5000 W) and short-term motor-starting output (800-6000 W). Size against the starting figure with margin, and treat the peak figure as a surge rating, not a continuous one. Then decide how many full open/close cycles the site needs during an outage; the built-in battery strings run from 7 Ah x 2 on the 6D to 12 Ah x 8 on the 50D, and we size the pack against that cycle count.
Output voltage and phase are factory builds. Confirm 220 Vac single phase or 380 Vac three phase against the site supply before ordering — a 110 V version or a different plug is an OEM configuration, not a switch on the back of the unit. MOQ, lead time and private-label options are confirmed at quotation.
Product views
Models in this series: EPS 6D, 7D, 12D, 20D, 30D and 50D. Photographs show the series enclosures; finish and port layout vary by configuration. Select a view to open the full-size image.
Related HighIdea products
This model is the first purpose-built series in the Special-Purpose UPS sub-category — one of the seven sub-categories under UPS Power Supply, reserved for UPS systems engineered for one specific operating scenario. Further scenario-specific series are added there as they are released. For general backup of PCs and office equipment, see the Offline UPS range; for transformer-isolated heavy industry systems, see Industrial UPS. The full UPS Power Supply category lists all seven sub-categories.
Key Features
- Pure sine wave output with boost and buck AVR for unstable mains
- Six models: 600-5000 W rated, 800-6000 W motor-starting output
- Single-phase 220 V (6D/7D/12D/20D) and three-phase 380 V (30D/50D)
- Built-in VRLA battery strings from 7 Ah x 2 up to 12 Ah x 8
- Microprocessor control, wide LED/LCD status display, intelligent battery management
- Under 8 ms transfer on single-phase models, under 8 s on three-phase models
- Short-circuit, over/under-voltage, surge, lightning, low-battery and >120% overload protection
- Cold start, energy-saving mode and optional 433 MHz remote control
- Wall-mount boxes from 308x226x96 mm; three-phase cabinets up to 710x400x180 mm
Applications
Roller shutters and garage doors
A stalled shutter is a locked entrance. The 6D to 20D wall-mount units keep homes, shops and loading bays operable during an outage.
High-speed and industrial doors
Fast doors, sectional doors and sliding gates draw a heavy inrush on every start; the motor-starting rating and surge protection are sized around that duty.
Three-phase door groups
EPS 30D and 50D cabinets supply 380 Vac three-phase door banks in factories, logistics centres and large parking structures.
Unattended sites with poor mains
Boost/buck AVR, wide 160-270 Vac or 330-415 Vac input window and automatic charging suit plant rooms and remote gates where nobody checks the supply.
FAQ
Is this a UPS or an EPS?
Which model do I need for my door motor?
What is the difference between the two output power figures?
Do you have 110 V versions?
Is a remote control included?
Related Models
Industrial UPS
Transformer-isolated power-frequency UPS from 6 to 600kVA — built for hostile grids, inductive loads and sites where galvanic isolation is non-negotiable.
View detailsOffline UPS
Cost-effective backup power for PCs, routers, POS terminals and home office equipment.
View detailsSpecial-Purpose UPS
A special-purpose UPS is specially engineered for one operating scenario and built to serve that scenario alone. This sub-category of UPS Power Supply holds one dedicated series per scenario as they are released.
View detailsSpecification reference
| Parameter | EPS 6D | EPS 7D | EPS 12D | EPS 20D | EPS 30D | EPS 50D |
|---|---|---|---|---|---|---|
| Output | ||||||
| Rated output power (W) | 600 | 700 | 1200 | 2000 | 3000 | 5000 |
| Motor-starting output (W) | 800 | 1300 | 1500 | 2600 | 4000 | 6000 |
| Output voltage (Vac) | 220 | 220 | 220 | 220 | 380 | 380 |
| Output frequency | 50/60 Hz +/-2% | |||||
| Output waveform | Pure sine wave | |||||
| Transfer time | <8 ms | <8 ms | <8 ms | <8 ms | <8 s | <8 s |
| Input | ||||||
| Input voltage (Vac) | 160-270 | 160-270 | 160-270 | 160-270 | 330-415 | 330-415 |
| Input frequency | 50/60 Hz +/-5% | |||||
| Battery & charging | ||||||
| Built-in battery | 7 Ah x 2 | 9 Ah x 2 | 7 Ah x 4 | 9 Ah x 4 | 9 Ah x 7 | 12 Ah x 8 |
| Charge current (A) | 1-3 | |||||
| Charge mode | Automatic on start-up | |||||
| Protection | ||||||
| Protection | Output short, over/under voltage, mains short, low battery, lightning and surge | |||||
| Overload protection | Auto shutdown above 120% load | |||||
| Mechanical | ||||||
| Dimensions L x W x H (mm) | 308x226x96 | 308x226x96 | 308x285x120 | 308x285x120 | 550x400x180 | 710x400x180 |
| Package size (mm) | 385x340x300 | 385x340x300 | 485x396x215 | 485x396x215 | 630x470x265 | 800x470x265 |
| Net / gross weight (kg) | 6.5 / 7.5 | 7.5 / 8.5 | 13 / 15 | 15 / 16.5 | 48 / 50 | 71 / 74 |
Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.
Specifications subject to the latest revision; need other technical documents? Ask our engineers.