RT Series 30-800A Embedded Switching Power System

A modular 48V DC plant that scales from 30 to 800A — hot-swap rectifiers, full battery management and remote monitoring.

RT48 Series (30-800A) Product image
Appearance may vary by configuration; final specifications per quotation.
Brand
HighIdea
Type
Modular 48VDC embedded switching power system
Typical applications
Telecom base stations, small and medium switching offices, microwave and satellite communication, data communication, data rooms
Models in range
30 - 800A configurations, 48VDC rectifier modules (hot-swap), AC or DC input variants
Category
Switching Power Supplies & Rectifiers

The RT48 Series is a modular embedded switching power system with a total capacity of up to 800A. It integrates the telecom power plant, AC and DC distribution, temperature control and monitoring in one frame, with comprehensive battery management, load and battery low-voltage protection, energy metering, temperature compensation, automatic voltage regulation, current limiting, battery capacity calculation, online battery testing and sleep-mode energy saving.

Design notes

Digitally controlled active power-factor correction keeps input PF above 0.99 and limits harmonic pollution of the grid. Rectifier modules use non-damaging hot-swap technology and can be replaced in under a minute. An ultra-wide input window suits harsh grids and extends battery service life; AC and DC input versions are available. Full battery management includes LVLD + LVBD and a secondary disconnect stage, while both LiFePO4 and VRLA strings are supported. The networked controller offers RS232 / RS485 and dry contacts for flexible remote monitoring and unattended operation, with AC- and DC-side lightning protection, complete fault protection, alarms and a stored event history. All operation and maintenance is from the front, so the cabinet can be placed against a wall.

Configuration

State the present load current and the growth target, the input source, the number of rectifier modules and N+1 spare count, battery chemistry and capacity, distribution breaker layout, LVLD / LVBD setpoints and the monitoring protocol. For a compact fixed 48V system see the RT4860; where only the DC voltage needs changing see the RP DC-DC Converter.

Key Features

  • Total system capacity up to 800A with modular hot-swap rectifiers
  • Module replacement in under one minute with no damage or output interruption
  • Active power-factor correction with input PF above 0.99
  • Complete battery management: LVLD + LVBD, secondary disconnect, temperature compensation
  • Automatic boost / float control, voltage regulation, current limiting and battery capacity calculation
  • Online battery testing and sleep mode for energy saving
  • RS232 / RS485 and dry-contact interfaces for unattended remote monitoring
  • Full front access allows wall-mounted installation to save floor space
  • Works with both LiFePO4 and VRLA battery strings

Applications

Telecom base stations

Unattended 48V plants with remote monitoring and automatic battery protection.

Switching & data rooms

High-capacity modular DC plant that grows with the load.

Microwave & satellite links

Sites with harsh mains, wide input tolerance and no on-site staff.

FAQ

How is capacity expanded?
Add hot-swap rectifier modules to the frame. Modules can be inserted or replaced in under a minute while the system stays live, up to a total of 800A.
Which battery chemistries are supported?
Both LiFePO4 and VRLA strings. Charge parameters, temperature compensation, capacity calculation and disconnect setpoints are configured for the selected chemistry.
What does LVLD + LVBD protect?
Low-voltage load disconnect sheds non-critical loads first, and low-voltage battery disconnect protects the battery from deep discharge. A secondary disconnect stage separates further loads as the bus keeps falling.
Can the system run unattended?
Yes. RS232 / RS485, dry contacts, fault display, alarm history, remote monitoring and automatic recovery are designed for unattended base stations.

Related Models

Specification reference

DC output voltage48 VDC
System capacity30 - 800 A
InputAC or DC input versions, ultra-wide input voltage range
Power factor>= 0.99 (active PFC, digital control)
Rectifier modulesHot-swappable, replacement < 1 min
Battery managementLVLD + LVBD, secondary disconnect, temperature compensation, auto boost / float
Battery testingCapacity calculation and online battery test
MonitoringRS232 / RS485, dry contacts, remote alarm and event history
ProtectionInput / output over- and under-voltage, short circuit, over-current, lightning, fan failure
Battery compatibilityLiFePO4 and VRLA
AccessAll front-side operation and maintenance

Specifications subject to the latest factory data. Final configuration is sized against the actual load, backup runtime and site power conditions — this table is for pre-selection only.

Email Us WhatsApp